PEMBUATAN ELEKTRODA SELEKTIF ION Cr (VI) DENGAN MENGGUNAKAN MEMBRAN KITOSAN
Abstract: This research was
aimed to make and to determine analytical performance of Cr (VI) ISE. The electrodes has made by
mixing Chitosan(as electroactive), PVC (as matrix), and DBP (as plasticizer) in
THF. Composition of PVC and DBP maintane in fix ratio, 1: 2, while the chitosan
varried, 4%, 7%, 10%, 13% and 16%. The composite membrans soak into 1M K2Cr2O7
solution for the night, then tight on the tip of electrode body. Analytical
performance of the electrodes were determined by nersnt factor and dynamic
range, response time, selectifity coeficient, and life time. The results show
that the electrodes with composition 4 % chitosan, 32 % DBP, and 64 % PVC have
optimum performance. Dynamic range of this electrodes is between 10-5 M - 10-1
M , slope/nersnt factor 32.004 mv/decade, average response time 20.7 seconds.
The electrodes are not interfered by
Mn2+, Zn2+ and Fe3+. The electrodes can used with good performance in 3
days.
Penulis: Agus Kembaren, Roita
T.T Panggabean
Kode Jurnal: jpkimiadd140852