Abstract: The purposes of this research is to assess the illuminating of in classroom 35C 201 40 and 35C 210 40 phycics building University of Jember.Data retrieved by using a lux meter, with three times the measurement at everypoint. After data was obtained from calculation, so the data will be enteredinto Software Calculux Indoor 5.0b. Based on the research that has been done,it showed that in classroom 35C 201 40 and 35C 210 40 not in accordancewith the standard set by Indonesian National Standard of 250 lux, with result 79,59 lux and 77,05 lux. Whereas the result of the measurement and calculation of the reflectances values on both the classroom to the walls, floor, and ceiling has been corresponding of Indonesian National Standard recommendations with a value from 0.5 until 0.8. In accordance with thetheory of illumination for Indonesian National Standard must full fil thecriteria: cleanliness of the room, the installation of the armature and the light evenly, giving the bright color of the walls, floors, and ceilings. The simulation result from Software Calculux Indoor 5.0b that is the illuminations atclassroom 35C 201 40 better than 35C 210 40. The illumination in bothclassroom not in accordance with the standard set by Indonesian NationalStandard, so that it can affect of the learning process.
Keywords: Illumination, Point of Measurement, Classroom 35C 201 40 and 35C 21040