ANALISIS POTENSI RESAPAN DI DAERAH ALIRAN SUNGAI CISADANE HULU
ABSTRACT: Human disturbance
such as land use changes, urbanization, and deforestation degrade Upper Cisadane
Watershed. It also causes degradation of recharge area, decrease infiltration
and increase runoff. The aims of this research were to (1) identify the
criticality of recharge area; and (2) analyze the potentialof water recharge in
Upper Cisadane Watershed. The criticality of recharge area had been identified
refersto regulation of the Minister of Forestry, Republic of Indonesia Number:
P.32/MENHUT-II/2009 byscoring and overlaying of slope, soil type, rainfall, and
land use map. The amount of water rechargepotential was predicted by the
equation issued by IWACO and WASECO (1990). The result showed thatdistribution
of criticality of recharge area in Upper Cisadane Watershed in 2006, 2009, and
2013 were: (1) good: 24.7%, 24.7%, 23.6%; normal: 6.9%, 6.2%, 3.7%; (3) ranging
critical: 17.9%, 17.8%, 19.4%, (4) rather critical: 25.0%, 24.9%, 30.7%; (5)
critical: 23.9%, 24.5%, 22.0%; and (6) very critical: 1.9%,2.0%, 0.7%
respectively. The magnitude of the potential of water recharge on average in
the recharge area was in good condition; 154.5 x 106 m3, normal; 33.9 x 106 m3,
ranging critical; 94.6 x 106 m3, rather critical; 130.9 x 106 m3, critical;
98.2 x 106 m3, very critical; 6.2 x 106 m3. Upper Cisadane Watershed has a
potential of annual water recharge was 511.7 x 106 to 569.2 x 106 m3/year or
around 14% - 15.6% of total rainfall, with an average change in the potential
of water recharge from the simulation based on the condition of recharge area
in 2006-2009 decreased -0.04%, in 2009-2013 decreased -3.2% and in 2006-2013
decreased -3.3%.
Penulis: Radius Pranoto,
Satyanto Krido Saptomo, Roh Santoso B. Waspodo
Kode Jurnal: jptsipildd160420

Artikel Terkait :
Jp Teknik Sipil dd 2016
- STABILITAS STRUKTUR BAWAH BANGUNAN LEPAS PANTAI UNTUK FLOATING WIND TURBINE DENGAN SISTEM TENSION LEG-SPAR PLATFORM
- PERENCANAAN ALTERNATIF MASJID RAYA AN – NUR POLITEKNIK NEGERI MALANG DENGAN MENGGUNAKAN PROFIL CASTELLATED BEAM NON KOMPOSIT
- KURVA BELAJAR UNTUK PEMASANGAN DINDING PARTISI PADA PEMBANGUNAN GEDUNG SENTRAL FAKULTAS PERTANIAN TAHAP III UB MALANG
- PENGARUH PENAMBAHAN KAPUR DENGAN LAMANYA WAKTU PERAWATAN (CURING) TERHADAP KEKUATAN DAN PENGEMBANGAN (SWELLING) TANAH LEMPUNG EKSPANSIF
- PENGARUH RASIO LUAS PADA CAMPURAN KAPUR (LIME) TERHADAP HEAVE TANAH LEMPUNG EKSPANSIF PADA DEEP SOIL MIXING
- PENGARUH KADAR AIR DILAPANGAN DAN RATIO AIR – FLY ASH TERHADAP KEKUATAN DAN PENGEMBANGAN TANAH EKSPANSIF UNTUK METODE DSM (DEEP SOIL MIXING)
- PENGARUH RATIO SLURRY AIR-KAPUR PADA STABILISASI TANAH LEMPUNG EKSPANSIF UNTUK METODE DSM
- ANALISIS RISIKO KESELAMATAN DAN KESEHATAN KERJA (K3) DENGAN METODE HAZARD ANALYSIS DAN CONSEQUENCE – LIKELIHOOD ANALYSIS (STUDI KASUS PADA PROYEK PEMBANGUNAN GEDUNG BARU FAKULTAS ILMU ADMINISTRASI UNIVERSITAS BRAWIJAYA)
- PENETAPAN TARIF JALAN TOL BERDASARKAN PENDEKATAN ATP DAN WTP (STUDI KASUS: RENCANA JALAN TOL SOLO – KARANGANYAR)
- PENERAPAN METODE MONTE CARLO UNTUK ALOKASI KONTIGENSI BIAYA PADA PEMBANGUNAN GEDUNG KANTOR DINAS KEPENDUDUKAN DAN CATATAN SIPIL KECAMATAN PACITAN
- ANALISIS KUAT GESER PADA PEMANFAATAN BATU APUNG BERLAPIS CAT SEBAGAI ALTERNATIF PENGGANTI AGREGAT KASAR PADA BETON
- ANALISIS REGANGAN DAN POLA RETAK YANG DIAKIBATKAN BEBAN GESER PADA BETON RINGAN BERAGREGAT KASAR BATU APUNG YANG DIBERI LAPISAN CAT KERAMIK
- PENGARUH VARIASI KONFIGURASI PORTAL GEDUNG TIGA DIMENSI TERHADAP PERFORMA STRUKTUR SAAT PENGUJIAN GAYA GEMPA DUA ARAH
- KAJIAN KINERJA PELAYANAN SISI DARAT BANDAR UDARA NOTOHADINEGORO KABUPATEN JEMBER DAN POTENSI PENUMPANG PESAWAT TERBANG RUTE JEMBER – DENPASAR
- ANALISIS VARIASI KONFIGURASI STRUKTUR PORTAL TIGA DIMENSI TERHADAP BEBAN GEMPA
- ANALISIS PENGARUH KONFIGURASI DAN OPTIMASI PADA JEMBATAN RANGKA BAJA TERHADAP EFISIENSI JEMBATAN
- PENGARUH PENGENCANGAN BAUT TERHADAP LENDUTAN PADA MODEL JEMBATAN RANGKA BAJA
- PENGARUH PENGENCANGAN BAUT TERHADAP FREKUENSI NATURAL PADA MODEL JEMBATAN RANGKA BAJA
- MANFAAT SUMUR RESAPAN DALAM PENANGGULANGAN BANJIR DI WILAYAH KELURAHAN PENANGGUNGAN BAGIAN SELATAN KOTA MALANG
- PENGARUH PERBAIKAN TANAH LEMPUNG EKSPANSIF DENGAN METODE DEEP SOIL MIXING PADA BERBAGAI KADAR AIR LAPANGAN TANAH ASLI TERHADAP NILAI CBR DAN PENGEMBANGAN
- KUAT LENTUR BALOK BETON TULANGAN BAMBU PETUNG VERTIKAL TAKIKAN TIDAK SEJAJAR TIPE U LEBAR 3 CM TIAP JARAK 15 CM
- KUAT LENTUR BALOK BETON TULANGAN BAMBU PETUNG VERTIKAL TAKIKAN TIDAK SEJAJAR TIPE U LEBAR 1 CM TIAP JARAK 15 CM PADA KULIT BAMBU DI SISI DALAM
- KUAT LENTUR BALOK BETON TULANGAN BAMBU PETUNG VERTIKAL TAKIKAN TIDAK SEJAJAR TIPE U LEBAR 2 CM TIAP JARAK 15 CM DENGAN POSISI KULIT BAMBU DI SISI DALAM
- STUDI PERBANDINGAN ESTIMASI KESALAHAN PADA LINEAR MODEL DAN INSTANTANEOUS MODEL DALAM MENGESTIMASI WAKTU PERJALANAN BERBASIS KECEPATAN SESAAT (LOKASI STUDI : RING ROAD UTARA SURAKARTA)
- KUAT LENTUR BALOK BETON TULANGAN BAMBU PETUNG VERTIKAL TAKIKAN TIDAK SEJAJAR TIPE U LEBAR 1CM TIAP JARAK 15CM