EVALUASI KETAHANAN GEMPA PADA STRUKTUR GEDUNG X DI JAKARTA BERDASARKAN SNI 03-1726-2012

ABSTRACT: Earthquake risk in Jakarta is the intermediate category in Indonesia based on the 2010 seismic hazard map published by the Ministry of Public Works, Republic of Indonesia. It was important to know the conditionof the building that would be affected by earthquake load and to prevent collapse of the building structuresthat could cause loss of live people in the building and the collisions between buildings. The purpose of this research was to know the ultimate performance limit of the existing X building in Jakarta. Evaluation of these building was based on guidelines SNI 03-1726-2012, SNI 03-2847-2013 and PPPURG 1987. The structure model of X building was designed and analyzed using ETABS Version 9.7.2. The result showed value of story drift was affected by dynamic response spectrum load, the maximum drift in x–direction is68.60 mm and y–direction is 101.2 mm. The X building was declared unsafe in performance condition of the ultimate limits.
Keywords: building, earthquake, respon spectrum analysis, story drift
Penulis: Sayed Ahmad Fauzan, Erizal, Asep Sapei