METODE SINKRONISASI INVERTER SATU FASE DENGAN JARINGAN LISTRIK YANG TERDISTORSI
Abstract: DC power sources
from renewable energy sources that would be connected to the electricity grid
system require synchronization process. This process is implemented by
controlling the inverter in a way to obtain instantaneous amplitude, phase and
frequency according to the electricity network. This research discussed a
method for synchronizing VSI PWM inverters connected with distorted
single-phase power grid using a filter as a pure sine generator, and a
compensator as the restorer of angle change due to the power filtering. Results
of simulation using MATLAB show that this method can produce better
synchronization compared to other synchronization methods, as it successfully
produce similar phase and waveform with the grid’s waveform.
Penulis: Bambang Sujanarko
Kode Jurnal: jptkomputerdd100026

Artikel Terkait :
Jp Teknik Komputer dd 2010
- APLIKASI NEURAL NETWORK PADA SYSTEM CONTROL TURBIN MIKRO HIDRO
- PENEMUAN RUTE TERPENDEK PADA APLIKASI BERBASIS PETA
- RANCANG BANGUN APLIKASI SMART CARD INTERFACE
- RANCANG BANGUN SISTEM INFORMASI GEOGRAFIS PENGUASAAN PEMILIKAN PENGGUNAAN DAN PEMANFAATAN TANAH (P4T) KABUPATEN JEMBRANA BERBASIS WEB
- Cognitive Radio: Sistim Radio Cerdas
- Pengaruh Perilaku Konsumen Mobile Internet Terhadap Keputusan Pembelian Paket Layanan Data Unlimited Internet CDMA di DKI Jakarta
- Penggelaran Teknologi HSPA+ di Indonesia
- Perencanaan Strategi Penerapan Teknologi DVB-T di LPP TVRI
- Menentukan Optimasi Routing dengan Pengaturan Route Advertisement pada Jaringan Mobile IPV6
- Steady-State Stability Assessment Using Neural Network Based on Network Equivalent
- An Adaptive Modulation in Millimeter-Wave Communication System for Tropical Region
- High Performance Palmprint Identification System Based On Two Dimensional Gabor
- Chaos on Phase Noise of Van Der Pol Oscillator
- A Video Streaming Application Using Mobile Media Application Programming Interface
- Distributed Monitoring and Controlling Using Microcontroller and Virtual Internet Protocol
- A Novel Dynamic Overmodulation Strategy of Direct Torque Control
- A Simple Instrumentation System for Large Structure Vibration Monitoring
- An Automatic Identification System of Human Skin Irritation
- Lag-Lead Compensator for Shape Memory Alloy in Gripping Manipulation
- Harmonic Mitigation Using a Polarized Ramp-time Current-Controlled Inverter
- Hybrid Methods in Designing Sierpinski Gasket Antennas
- Satellite Imagery and In-situ Data Overlay Approach for Fishery Zonation
- Fast Geometric T2-Fuzzy Based Improved Lower Extremities Stimulation Response
- Cost and Benefit of Information Search using Two Different Strategies
- TURTLE HEARING CAPABILITY BASED ON ABR SIGNAL ASSESMENT